The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.
Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.
The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.
| Inspection # 9917955 | ||
|---|---|---|
| VIOLATIONS | BUILDING CODE CITATION | VIOLATION DETAILS |
| CN138106 | Remove and stop nuisance. (7-28-060) | Rear porch - Firewood stacked at stored at 2nd and 4th floors. |
| CN190019 | Arrange for inspection of premises. (13-12-100) | No entry. Caller stated in complaint that she'd already moved out. Manager not on site. Unable to inspect interior, stairwell, apartments, basement, and rear porch. Unverified detectors and occupancy. |
| CN190029 | pending notice reinspection | Recently built rear porch. Plans and permit not available for review at time of inspection. |
| CN194029 | Provide | Rear parking lots - Horizontal vehicular barriers attached to concrete slab are too close to concrete piers of rear porch. Vertical vehicular barriers missing; vehicles coming into contact with piers despite existing barriers. (Sec. 7-28-060) |
| CN198019 | File building registration statement with Building Dept. (13-10-030, 13-10-040) | Not registered 2009-2011 |
| NC2011 | Performed or allowed work to be performed without submitting plans prepared, signed and sealed by a licensed architect or registered structural engineer for approval and without obtaining a permit to perform the work. (13-32-010, 13-32-040, 13-40-020, 13-12-050) | Recently built rear porch. No permit obtained. |