The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 4130 S INDIANA AVE
Inspection # 12374822
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN015022 Failed to hang exit door to swing in direction of exit travel in residential buildings where exit door serves more than one dwelling unit or in any building where exit door serves more than 50 persons. (13-160-250) 1st fl 7& Basement Exit Gate & Doors Swing in
CN015062 Failed to remove obstruction from exitway that hampers travel and evacuation. (13-160-070, 13-196-080) 2nd floor Chapel & Basement Gate Padlocked
CN017012 Failed to use materials with appropriate fire resistance to finish interior wall, ceiling and interior trim. (15-8-370, 15-8-380 thru 15-8-430) Provide Class 2 Flame Spread Rating on all paneling
CN061014 Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641) All Elevations Fractures, Loose Mortar & Spalling Brick throughout
CN062034 Failed to maintain roof coping in good repair and free from cracks defects. (13-196-530, 13-196-530(c) and 13-196-641) Open cooing joints all elevations: Loose Stone copings all Elevations: East Elevation Top Peak Stone Leaning (D & H)
CN067014 Failed to maintain roof in sound condition and repair, watertight and free from defects. (13-196-530, 13-196-530(c) and 13-196-641) Loose & Missing Roofing at various locations
CN070014 Failed to maintain exterior stairways in safe condition and in sound repair. (13-196-570, 13-196-641) Rear Basement Missing Handrails
CN074024 Failed to provide porch which is more than two risers high with rails not less than three and one-half feet above the floor of the porch. (13-196-570(b), 13-196-641 Rear Basements missing gaurdrails
CN077024 Failed to remove barbed wire from fence less than eight feet in height. (13-96-160) Rear Fence has Barbed Wire alley side at 5" High
CN101015 Failed to maintain interior walls and ceilings free from holes or cracks. (13-19-540(c)) Basement, 1,2,& 3 Floors (Front & Rear Rooms) -Loose missing Plaster & Paint through out ceiling & wall, Loose wallpaper at Front 1st floor vestibule
CN103015 Failed to maintain floor free from holes and wide cracks and free from loose, warped, protruding or rotting floor boards. (13-196-540(a) and (b)) 1,2 & 3 Floors Loose & Missing Floorings & Tiles through out
CN103025 Submit plans prepared, signed, and sealed by a licensed architect or registered structural engineer for approval and obtain permit. (13-196-030) Structural Engineers Report for sinking & leaning Front Stairs and Condition if Whole Building
CN104015 Replace broken, missing or defective window panes. (13-196-550 A) Missing Window Panes through out all elevations
CN104035 Failed to maintain windows in sound condition and good repair. (13-196-550(b) and (f)) Rotted Window Frames through out all Elevations,
CN106015 Failed to maintain interior stairway system in safe condition and sound repair. (13-196-570) Front Main Stairs from basement to 2nd floor-Leaning and sinking with missing & incomplete Handrails through out all Stair Systems (Basement-3 flr,uneven bottom risers at front 1st floor stairs
CN134076 Provide self-closing device for basement door to prevent entry of rats. (13-196-530 D, 7-28-660, 7-28-700) Rat Proof Basement Door
CN138056 Remove accumulation of refuse and debris and keep premises clean. (13-196-580, 13-196-630) Excessive Junk & Debris a Front Basement
CN138086 Elevate wood, lumber or other material 18 inches above ground to eliminate rat harboring places or remove from premises. (7-28-720) Elevate any storage abating Rat Harborage at Basement
CN194019 Repair or replace Rear 1st & 3rd Floors Vacant & Exposed to Elements with Mechanical Systems partially removed Replace missing windows & Restore Mechanical Systems to protect interior from additional damage, Vacant & open conditions promoting & accelerating interior damage 13-196-630,13-196-540(a,b,c) + 13-196-550 (a,b,c)
CN194029 Provide Rear Basement Exit Doors not 36" (831 x 354" )(13-160-2)
NC2011 Performed or allowed work to be performed without submitting plans prepared, signed and sealed by a licensed architect or registered structural engineer for approval and without obtaining a permit to perform the work. (13-32-010, 13-32-040, 13-40-020, 13-12-050) Plans & Permits for 2nd floor Chapel, Basement Hall & Kitchen use and Alterations,Construction of Basement Kitchen For All Repairs