The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 2224 S SACRAMENTO AVE
Inspection # 12671465
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN061014 Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641) FRONT BUILDING - EXTERIOR MASONRY WALL FRONT AND SOUTH ELEVATION SPALLED BRICK AND WASHED OUT MORTAR JOINTS.
CN070024 Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641) FRONT BUILDING - REAR ENCLOSED PORCH: GRADE TO ATTIC EXPOSED STUDS; FOUNDATION - NOT VERIFIED; LEDGERS - ALL NAILED CONNECTIONS; JOIST - IMPROPER CONNECTIONS, MISSING HANGERS; BEAMS - NOTCHED IN; COLUMNS - OVER NOTCHED; DECKING - PULLING AWAY FROM BUILDING, WITH EXCESSIVE SLOPE; RAILINGS - BELOW REQUIRED HEIGHT, HORIZONTAL, EXCESSIVE SPACING, AND DEFLECT UNDER LOAD. PLANS AND PERMITS ARE REQUIRED.
CN073014 Failed to maintain exterior door in sound condition and repair. (13-196-550(d) and (e), 13-196-641) FRONT BUILDING - 3RD FLOOR REAR DOOR DISCONNECTED FROM HINGES.
CN077014 Failed to maintain fence in good condition and repair. (7-28-060, 13-196-630, 13-196-641) IRON FENCE AT EAST ELEVATION DETACHED FROM POST.
CN111025 Provide sufficient means of egress. (13-196-050, 13-196-650, 13-196-740 B, 13-200-230 F) FRONT BUILDING - BASEMENT UNIT EGRESS INSUFFICIENT FRONT EXIT 31" X 6'6", REAR 30" X 4'7" AND INOPERABLE BLOCKED BY STAIR SYSTEM TO 1ST FLOOR FROM EXTERIOR.
CN136016 Exterminate roaches and keep dwelling insect-free. (13-196-630 C) FRONT BUILDING - EVIDENCE OF ROACH INFESTATION.
CN197019 Install and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window. FRONT BUILDING - MISSING SMOKE DETECTORS 2ND FLOOR, BASEMENT, AND REAR PORCH. DANGEROUS AND HAZARDOUS.
CN197079 Repair or replace defective or out of service smoke detectors and operate continuously. (13-196-130, 13-196-140) FRONT BUILDING - 3RD FLOOR SMOKE DETECTOR MISSING BATTERY, DANGEROUS AND HAZARDOUS.
CN197087 Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries. FRONT BUILDING - MISSING CARBON MONOXIDE DETECTOR 2ND FLOOR AND BASEMENT, 3RD FLOOR BATTERY REMOVED. DANGEROUS AND HAZARDOUS.
EL1819 Replace defective light fixtures. (14E-4-410.20, 14E-4-410.21, 14E-4-410.22, 14E-4-410.23) FRONT BUILDING - REPLACE FIXTURE WHITE CHANDELIER WITH SPLICE WIRES IN 1ST FLOOR UNIT.
NC2071 Remove work performed without permit and restore building or site to original construction. (13-32-130, 13-32-290) FRONT BUILDING BASEMENT - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT.