The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 1115 S TROY ST
Inspection # 14212242
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN073014 Failed to maintain exterior door in sound condition and repair. (13-196-550(d) and (e), 13-196-641) REAR DOOR BROKEN OFF HINGES AT EAST ELEVATION.
CN102015 Failed to maintain interior walls, ceilings and woodwork free from flaking, peeling, chipped or loose paint. (13-196-540(d)) BATHROOM CEILING WATER DAMAGED
CN197079 Repair or replace defective or out of service smoke detectors and operate continuously. (13-196-130, 13-196-140) MISSING SMOKE DETECTORS THROUGHOUT PROPERTY
CN197087 Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries. MISSING CARBON MONOXIDE DETECTOR THROUGHOUT PROPERTY
EL1816 Install additional receptacle outlets. (14E-5-560.6, 14E-5-570.10(e))
EL1819 Replace defective light fixtures. (14E-4-410.20, 14E-4-410.21, 14E-4-410.22, 14E-4-410.23)
EL1827 Restore exit and emergency lighting system and related equipment to working condition. (14E-7-700.6)
EL1886 NO SIGN OF MAIN WATER GROUND.
EL1886 Need electrical permit to correct violations. 14A-4-404.6
PL159017 Repair or replace broken or defective plumbing fixture. (18-29-102.3), (18-29-402.1), (18-29-402.1.1) broken tilet plumbing fixture in bathroom pf 2 rear apartment D&H
PL170017 Provide floor drain with metallic strainer. (18-29-402.5) no floor drain loated in mechnical room of apartment D&H
PL171017 Obtain permit for plumbing work before undertaking work. (18-29-106.1)
PL171027 Employ licensed and bonded plumber to perform plumbing work. (18-29-106.1 thru 106.2)
PL194029 Provide no safe pan under hot water tank in apartment 2 rear mechanical room 18.29.504.8 D&H
PL194029 Provide NO DIELETRIC UNIONS ON HOT WATER TANK POTABLE WATER CONNECTION OF APARTMENT 2 REAR
PL235050 Protect plumbing system pipes from external corrosion. (18-29-305.1) FROZEN PIPES IN BASEMENT OF APARTMENT BUILDINT NOT PROTECTED FORM FREEZING D&H
PL237058 Provide discharge pipe from water heater and hot water storage tank relief valve. (18-29-504.7.1) pvc at hot water tank t&p valve located in mechanical room D&H
PL238040 Provide sufficient water at plumbing fixture to stop unsanitary condition. (7-28-060, 18-29-602.2) no hot or cold water at kitchen faucet or any other bathroom fixtures hroughout building D&H