The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 6540 N GLENWOOD AVE
Inspection # 13020069
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN063014 Failed to maintain chimney in safe and sound working condition. (13-196-590, 13-196-530(b) and (c), 13-196-641) Southwest elevation /chimney - washed out mortar joints.
CN070024 Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641) Rear wood porch - Railing sections undersized at 36". Stringers fastened to headers with nails only. Columns have 12" splices with 2 thru bolts only. Plans and permit required for repairs.
CN073014 Failed to maintain exterior door in sound condition and repair. (13-196-550(d) and (e), 13-196-641) Front entrance door- Broken pane.
CN074014 Failed to maintain exterior service walks, passage and areaways in clean, sanitary and safe condition. (13-196-630, 13-196-641) Rear service walk - cracked and sinking concrete.
CN107035 Failed to maintain all exit signs illuminated when building is occupied and otherwise maintain exit signs in good condition. (13-196-090, 13-160-700 thru 13-160-770) Second floor at rear exit-Broken exit sign.
CN190029 pending notice reinspection Interior of building /no response. Unverified detectors and conditions. Unable to inspect interior stairway systems. Unverified complaint of Apt.101 - mold in bathroom.
CN197019 Install and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window. Laundry room-Missing smoke detector.
CN197087 Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries. Laundry room-Missing carbon monoxide detector.