The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 3024 W GUNNISON ST
Inspection # 14476829
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN015062 Failed to remove obstruction from exitway that hampers travel and evacuation. (13-160-070, 13-196-080) 3RD FLOOR REAR EXIT - BAGS OF STORAGE OBSTRUCTING EGRESS.(SEC 14X-5-505.1.2)
CN061014 Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641) SOUTH, WEST AND EAST ELEVATIONS - FRACTURES, LOOSE AND ERODED MORTAR AT VARIOUS LOCATIONS. (14X-3-303.1.1)
CN062014 Failed to maintain the parapet wall and coping in good repair and free from cracks and defects. (13-196-530, 13-196-530(e) and 13-196-641) EAST AND WEST ELEVATION - ERODED MORTAR WITH OPEN COPING JOINTS.(14X-3-303.6 )
CN063014 Failed to maintain chimney in safe and sound working condition. (13-196-590, 13-196-530(b) and (c), 13-196-641) EAST ELEVATION , NORTH CHIMNEY - FRACTURES, LOOSE AND ERODED BRICKS/MORTAR WITH MISSING CAP. PERMIT FOR REPAIRS REQUIRED.(SEC 14X-3-303.10)
CN101015 Failed to maintain interior walls and ceilings free from holes or cracks. (13-19-540(c)) 1ST, 2ND AND 3RD FLOORS - CRACKED AND WATER DAMAGED CEILINGS AT VARIOUS LOCATIONS.(14X-3-304.3)
CN106015 Failed to maintain interior stairway system in safe condition and sound repair. (13-196-570) FRONT AND REAR BASEMENT STAIRS - MISSING HANDRAILS.(14X-3-304.4)
CN132046 Provide and maintain every facility, piece of equipment, or utility in safe and sound working condition. (13-196-400, 13-196-440) BASEMENT - MALFUNCTIONING BOILER SHUT OFF, EMERGENCY GAS SHUT OFF BY FIRE DEPT. (14X-3-305.1, 14X-8-804.1 thru 14X-8804.4 and 14X-8-804.5) PROVIDE CONDITIONS ASSESMENT REPORT OF BOILER , FLUE AND CHIMNEY SYSTEMS PER SECTIONS (14X-1-1-4.1, 14X-1-104.2, 14X.1.104.3, 14X-1-104.4, 14A-4-411.1, 14A-4-412.1.1, 14A-6-603.5) PLANS AND PERMITS ARE REQUIRED PER REPORT FOR REPAIRS/REBUILD . ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL (SEC 14A-4-401.1)
CN138106 Remove and stop nuisance. (7-28-060) BASEMENT, 3RD FLOOR PORCH,FRONT & REAR STAIRWAY - EXCESSIVE STORAGE, RODENT/PEST HARBORAGE.(14X-1-103)
CN197019 Install and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window. 3RD FLOOR AND BASEMENT - MISSING SMOKE ALARMS. (14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 through 14B-9-907.2.10.7, and 14R-11-1104, 14X-5-504.8.4 ) PROVIDE 10YR BATTERY ALARMS THRU-OUT (14X-5-504.8.4)
CN197087 Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries. BASEMENT AND 3RD FLOOR - MISSING CARBON MONOXIDE ALARMS. (14X-5-504.9, 14B-9-915.1.1, 14B-9-915.2, and 14R-11-1105)
EL0029 Remove exposed wiring. (18-27-300.4) 3RD FLOOR AND BASEMENT - EXPOSED AND SHORTED WIRING. DANGEROUS AND HAZARDOUS. PLANS AND PERMITS ARE REQUIRED FOR ELECTRICAL REPAIRS . ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL BY THE ELECTRICAL BUREAU. (SEC 14A-4-404.1)