The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 4851 N DAMEN AVE
Inspection # 1958210
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN105015 Repair or replace defective door. (13-196-550) NO STAIRWELL DOORS CLOSE AND LATCH FLUSH-RESET ALL DOORS AT STAIRWELLS
CN194029 Provide LOW WATER PRESSURE, HOT SIDE OF FAUCET, APT. 3, 18-29-604.7
CN197019 Install and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window. TOO FEW SMOKE DETECTORS IN CORRIDORS-1 PER CORRIDOR-CORRIDOR LENGTH IS 100 FEET
EL0025 Install system III emergency lighting. (18-27-700.6, 18-27-700.22) INSTALL SYSTEM III EMERGENCY SYSTEM
EL0084 18-27-210.8 INSTALL GFCI'S IN WET LOCATIONS THRU-OUT BUILDING APTS.
NC5012 Failed to provide stairwell opening with self-closing, framed, 1-1/2 hour Class B door. (15-8-180) ALL STAIRWELL DOORS ARE NOT FIRE RATED, ALL DOORS MUST BE CLASS "B" RATED DOORS; ALL STAIRWELL DOORS HAVE HOLD OPEN DEVICES
NC5062 Failed to remove fusible links and/or other hold-open mechanism on stairwell doors in buildings where stairwells serve more than three floors. (15-8-180(c)) REMOVE ALL HOLD OPEN DEVICES. THESE ARE SUPPOSED TO BE DOORS DESIGNED TO PROTECT INTEGRITY OF STAIRWELLS DURING A FIRE
PL234002 Provide proper soil/waste vent pipe material. (18-29-702) REMOVE FLEX WASTE UNDER KITCHEN SINK, APT. 104, 18-29-702
PL237026 Provide water supply pipe with air chambers. (18-29-604.11), (18-29-604.11.1) PROVIDE AIR CHAMBERS ON WATER SUPPLIES FOR WASHING MACHINES, LAUNDRY ROOM, 18-29-604.11.1