The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 4407 N WOLCOTT AVE
Inspection # 2263889
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN063014 Failed to maintain chimney in safe and sound working condition. (13-196-590, 13-196-530(b) and (c), 13-196-641) rear chimneys fractures spalling brick, eroding mortar
CN069014 Failed to maintain foundation in sound condition and repair and so it adequately supports the building at all points. (13-196-530, 13-196-530(a), 13-196-641) fractured retainer wall rear basement stairway foundation at 4411
CN070014 Failed to maintain exterior stairways in safe condition and in sound repair. (13-196-570, 13-196-641) north & south west exterior to gang way broken treads, north & south exterior stairs missing hand rails.
CN074014 Failed to maintain exterior service walks, passage and areaways in clean, sanitary and safe condition. (13-196-630, 13-196-641) ALL REAR AND SIDE SERVICE WALKS WITH SEVERLY BROKEN/UNEVEN SECTIONS
CN104075 Failed to maintain windows in relation to the adjacent wall construction as to completely exclude rain and substantially exclude wind from entering the premises. (13-196-550(f)) ALL ELEVATIONS BROKEN/MISSING SECTIONS OF GLAZING (2) FLAKING PAINT (3) REAR FRAMES ROTTING EAST ELEV.
CN190019 Arrange for inspection of premises. (13-12-100) PROVIDE FULL INT. ACCESS TO VERIFY OCCUPANCY AND SAFETY DET.
NC2091 Perform construction according to approved plans or drawings. (13-32-120, 13-32-290) THE OPEN FRAME PORCHES WERE NOT ERECTED ACCORDING TO APPROVED PLANS/PERMITS. 1) THE FLOOR JOIST SPACING WIDER THAN INDICATED. 2) THE FRONT HEADER JOIST TYING INTO COLUMNS WERE NOT INSTALLED. 3) THE BEAM WALL POCKET IMBEDDED INTO WALL WAS NOT FOLLOWED THE METAL BRACKETS ALSO WERE INSTALLED ACCORDING TO DETAILS, THE BEAM TO COLUMN CONVECTION IS INTERIOR (WEAK). 4) THE TREAD SIZED NOT AT ADEQUATE SIZE. 5) STRINGER BOLTING METHOD INDICATED IN PLANS NOT FOLLOWED. 6) UNKNOWN FOOTING DEPTH UNDER LIGHT OF STAIRS COLUMNS. 7) JOIST TO BE INSERTED INTO BRICK WALL WERE NOT.
PL164057 Repair catch basin. (18-29-102.3), (18-29-1003.1 thru 1003.4) south center basin loose & fracture collar. south center catch basin sinking