City of Chicago
Building Permit and Inspection Records

Building Permit and Inspection Records

Disclaimer

The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 3532 N BROADWAY
Inspection # 2171911
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN070024 Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641) 4 south rear partially enclosed porches insufficiently supported cantirlevered structures with angled 4x4's in open masonry pockets, insufficient stringer to masonry connections, insufficient stringer to other wood member connections, no ledger bolts, no joist hangers. 2 center exterior porches & west porch. insufficient stringer anchors, insufficient railing anchors, missing joist hangers & ledger bolts where joists not masonry pockets, undersized guardrails. obtain plans & permits for porches.
CN074024 Failed to provide porch which is more than two risers high with rails not less than three and one-half feet above the floor of the porch. (13-196-570(b), 13-196-641 roof top deck with guardrail deficiencies. missing sections,undersized, broken sections, loose sections, deflecting rails.
CN190019 Arrange for inspection of premises. (13-12-100) no entry building interior
NC2011 Performed or allowed work to be performed without submitting plans prepared, signed and sealed by a licensed architect or registered structural engineer for approval and without obtaining a permit to perform the work. (13-32-010, 13-32-040, 13-40-020, 13-12-050) center west porch extends to roof, roof top deck & roof top shed provide plans & permits for shed & roof top deck.