The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.
Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.
The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.
| Inspection # 10564833 | ||
|---|---|---|
| VIOLATIONS | BUILDING CODE CITATION | VIOLATION DETAILS |
| CN060001 | Failed to provide 2 copies of a Critical Examination Report, sealed and signed by an Illinois licensed architect or structural engineer. (13-196-033, 13-196-034, 13-196-036) | Provide 100% hands on inspection , Exterior Wall Critical Exam all elevations : Submit report Jose Aparico , 120 N. Racine Chicago, Il 60607. |
| CN060002 | Immediately provide sidewalk shed for protection of property and passersby from unsafe conditions, as follows: (Sections 13-12-130, 13-20-040, 13-196-037(a)) | Front of Building - Immeadiately install heavy duty sidewalk canopy with permits from Dept. of Transportation to protect publicway from falling and loose stonework. |
| CN061014 | Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641) | Front of Building - Sixth floor terra-cotta window head stone missing with severely deteriorated backer iron lintel. Center sixth floor window head stones moved out , displaced and loose. Dangerous and Hazardous condition exist for publicway and passerbys . Provide protective sidewalk canopy with permits from the Dept. of Transportation. East , West and rear elevations . Concrete frame of building has loose , spalling and missing concrete with exposed and rusted rebars . Previous unpermitted concrete repairs are loose , fractured and moved out . Bricks and brickwork are severely spalled with washed out mortar and open mortar joints . Permits required for masonry repairs. |
| CN062024 | Failed to maintain parapet wall in good repair and free from cracks and defects. (13-196-530 and 13-196-641) | East , West and rear parapets spalled bricks with open mortar joints . West parapet at north end of building leaning inward . Permits required for brick and masonry repairs. |
| CN065014 | Failed to maintain lintel in good repair and free from cracks and defects. (13-196-530(e), 13-196-641) | Front window lintels rusted with flaking paint . Front at sixth floor where terra-cotta window head stone is missing , lintel iron severely deteriorated . Plans and permits required to replace or repair lintels. |
| CN076024 | Failed to maintain roof gutters and downspouts in good repair and working condition. (13-196-590, 13-196-630(b), 13-196-641, 18-29-1101, 18-29-1105, 18-29-1106) | Rear and side elevations - Gutters and downspouts severely rusted and deteriorated. |
| CN077014 | Failed to maintain fence in good condition and repair. (7-28-060, 13-196-630, 13-196-641) | Southeast iron areaway gate broken off hinges. |
| CN104025 | Failed to maintain window sash in good condition and so it fits reasonably tight within its frame. (13-196-550(b)) | Basement window sashes at East , West and rear, all plywood boarded. |
| CN134016 | Rid premises of rodents and seal rodent holes. (13-196-530 D, 13-196-540 A, 13-196-630 C) | Rats and rat holes at East , West and rear areaways. |
| CN137026 | Provide tight fitting impervious covers for garbage and refuse containers. (7-28-210) | Rear at alley - Metal trash carts overflowing trash with open lids. provide additional containers. |
| CN138056 | Remove accumulation of refuse and debris and keep premises clean. (13-196-580, 13-196-630) | West areaway trash , junk and debris. |
| CN138106 | Remove and stop nuisance. (7-28-060) | Rooftop elevator penthouse and mechanical room covered in spray painted graffiti . |
| CN196029 | Post name, address, and telephone of owner, owner's agent for managing, controlling or collecting rents, and any other person managing or controlling building conspicuously where accessible or visible to public way. (13-12-030) | Building - Post updated and complete owner's I.D. sign. |
| CN198019 | File building registration statement with Building Dept. (13-10-030, 13-10-040) | Building - Not registered 2010 through 2012 years . |