The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.

Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.

The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.

ADDRESS: 5218 S PRAIRIE AVE
Inspection # 11709680
VIOLATIONS BUILDING CODE CITATION VIOLATION DETAILS
CN077014 Failed to maintain fence in good condition and repair. (7-28-060, 13-196-630, 13-196-641) Toprails missing or bent on fence.
CN101015 Failed to maintain interior walls and ceilings free from holes or cracks. (13-19-540(c)) Shared bath loose plaster and peeling paint above the toilet. 1B-bath water damaged ceiling, loose plaster, peeling paint also.
CN104015 Replace broken, missing or defective window panes. (13-196-550 A) South-2nd floor, taped window pane cracked.
CN106015 Failed to maintain interior stairway system in safe condition and sound repair. (13-196-570) Pickets missing from handrail at 1st level. (Tenants blocked access to upper floors)
CN138106 Remove and stop nuisance. (7-28-060) Junk, furniture and debris in rear yard and on landings.
CN139016 Remove lid or door of abandoned refrigerator, ice box, or ice chest or remove from place accessible to children. (7-28-040) Old refrigerator stored on sidewalk.
CN165017 Replace defective bathroom floor with non-absorbent, water impervious, and easily cleanable material. (13-196-540 F) 1B-loose and cracked ceramic floor tiles in bath.
CN190019 Arrange for inspection of premises. (13-12-100) Unable to verify detectors and interior conditons and occupancy for entire building. No access to basement.
CN196029 Post name, address, and telephone of owner, owner's agent for managing, controlling or collecting rents, and any other person managing or controlling building conspicuously where accessible or visible to public way. (13-12-030) Owner's information sign missing address.
CN197019 Install and maintain approved smoke detectors. (13-196-100 thru 13-196-160) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window. 4-rooming units,(A,B,C,D) missing smoke detectors. There was NO detector in the rooms nor common area.
CN197087 Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries. 5218-1S: missing carbon monoxide detector.
CN198019 File building registration statement with Building Dept. (13-10-030, 13-10-040) Building not registered 2013-2015.
NC2011 Performed or allowed work to be performed without submitting plans prepared, signed and sealed by a licensed architect or registered structural engineer for approval and without obtaining a permit to perform the work. (13-32-010, 13-32-040, 13-40-020, 13-12-050) 6-DU converted to rooming units. Tenants blocked full access. No plans and permits authorising interior alterations.
PL157047 Stop leaking water. (18-29-102.3) Baths shows signs of leaking.