The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.
Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.
The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.
| Inspection # 2369562 | ||
|---|---|---|
| VIOLATIONS | BUILDING CODE CITATION | VIOLATION DETAILS |
| CN012022 | Failed to construct floor over basement with materials of at least one hour fire resistance, other than in single family and two family dwellings. (13-60-200) | south basement by laundry room-hole in ceiling-missing fire rating. |
| CN031023 | Failed to maintain properly charged fire extinguisher and to attach tag which clearly indicates recharge date and signature of the person who performed the recharge. (15-16-680) | south basement laundry room-outdated fire extinguisher tag-2005. |
| CN062024 | Failed to maintain parapet wall in good repair and free from cracks and defects. (13-196-530 and 13-196-641) | northwest parapet-loose brick and washed out mortar. |
| CN070014 | Failed to maintain exterior stairways in safe condition and in sound repair. (13-196-570, 13-196-641) | south basement stair to laundry room -missing handrail. |
| CN070024 | Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641) | 427,429 rear (side) enclosed stair systems with the following defects, under size bolts in stringers 3/8 must be 5/8 improperly spaced bolts in stringers to building at 32" must be 16", flaking and peeling paint throughout. Also same defects at 43, stair system, 429 1/2, 433 guardrails not bolted to building, improper center support for guardrails. Permits required for repairs. 8/31/09 work in progress. |
| CN073014 | Failed to maintain exterior door in sound condition and repair. (13-196-550(d) and (e), 13-196-641) | front entry door at 431n belden rubs. |
| CN101015 | Failed to maintain interior walls and ceilings free from holes or cracks. (13-19-540(c)) | south basement by laundry room-hole in ceiling. |
| CN104035 | Failed to maintain windows in sound condition and good repair. (13-196-550(b) and (f)) | west 3rd by porches-window frame loose and falling. |
| CN131016 | Screen outer doors, windows, and other outer openings adequately from April 15th to Nov 15th. (13-196-560 B) | Broken or torn window and door screens throughout. 8/31/09-not complied. |
| CN197039 | Relocate improperly installed smoke detectors. (13-196-110) Install a smoke detector in every dwelling unit. Install one on any living level with a habitable room or unenclosed heating plant, on the uppermost ceiling of enclosed porch stairwell, and within 15 feet of every sleeping room. Be sure the detector is at least 4 inches from the wall, 4 to 12 inches from the ceiling, and not above door or window. | relocate smoke detector from 2nd floor to top of 3rd floor. |
| CN197079 | Repair or replace defective or out of service smoke detectors and operate continuously. (13-196-130, 13-196-140) | 433 w belden -front stairway at top -non working smoke detector- south basement-laundry room non working smoke detector.also non working carbon monoxide detector in laundry room. |
| EL0036 | Install cover on outlet or junction box. (18-27-370.25) | basement laundry room, basement storage room, basement boiler room all have open electrical boxes. |
| NC2011 | Performed or allowed work to be performed without submitting plans prepared, signed and sealed by a licensed architect or registered structural engineer for approval and without obtaining a permit to perform the work. (13-32-010, 13-32-040, 13-40-020, 13-12-050) | Apt 201 at 433 removal of two interior walls, drywall from bathroom and kitchen, No permits on file. 8/31/09-not complied. |