The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed, or that work was performed in accordance with that permit and the requirements of the Municipal Code.
Information on inspections and alleged violations reflect conditions found by the inspector at the time of the inspection and not necessarily the current status of those alleged violations or the current condition of the property. The absence of alleged violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code.
The Department of Buildings may refer certain alleged violations to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County. Please contact the Department of Administrative Hearings or the Clerk of the Circuit Court, respectively to obtain records of these proceedings.
Inspection # 13618626 | ||
---|---|---|
VIOLATIONS | BUILDING CODE CITATION | VIOLATION DETAILS |
CN010012 | Failed to enclose heating plant room with noncombustible walls, partitions, floors and ceilings with at least one hour fire resistance. (15-8-190, 15-8-220) | FURNACE ROOM WALL INADEQUATE FIRE SEPARATION, PENETRATIONS AT WALL AND CEILING DANGEROUS AND HAZARDOUS, PERMIT REQUIRED 14B-5-509 |
CN011012 | Failed to provide self-closing, framed, 1-1/2 hour Class B fire door or other approved opening protective assembly for heating plant and/or boiler room. (15-8-230) | FURNACE ROOM DOOR MISSING DOOR CLOSURE DANGEROUS AND HAZARDOUS 14B-7-716 TBL-716.1(2) |
CN012022 | Failed to construct floor over basement with materials of at least one hour fire resistance, other than in single family and two family dwellings. (13-60-200) | BASEMENT CEILING EXCESSIVE WATER DAMAGED DRYWALL/WITH PENETRATIONS COMPROMISED FIRE SEPARATION DANGEROUS AND HAZARDOUS PERMIT REQUIRED 14B-6-605.4 |
CN015062 | Failed to remove obstruction from exitway that hampers travel and evacuation. (13-160-070, 13-196-080) | ALL REAR EXITS ARE OBSTRUCTED AND OR BLOCKED DANGEROUS AND HAZARDOUS 14X5-505.1.2 |
CN031033 | Failed to install approved fire extinguishers on every floor of commercial, industrial or storage building two or more stories in height and having floor area exceeding 3,000 square feet. (15-16-160, 15-16-640) | MISSING TAGGED, UP TO DATE, FIRE EXTINGUISHERS WITH SIGNAGE DANGEROUS AND HAZARDOUS 14X-5-504.5 |
CN032013 | Failed to limit supply of Class I flammable liquids (those with a flash point below 100 degrees F or 38 degrees C) to 10 gallons stored in approved safety cans of not more than one gallon capacity or provide approved flammable liquid storage room. (15-24-310(b)) | CORRIDOR PROPANE TANKS DANGEROUS AND HAZARDOUS (15-24-310CB) 14B-33-3317.1 |
CN061014 | Failed to maintain the exterior walls of a building or structure free from holes, breaks, loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the walls. (13-196-530(b), 13-196-641) | EXTERIOR WALLS STRESS FRACTURES,SHIFTED BRICKS AND WASHED OUT MORTAR JOINTS ALL ELEVATIONS PERMIT REQUIRED 14X3-303.1.1 |
CN061024 | Failed to maintain building or structure in a structurally safe and stable condition. The Building Commissioner requests submission of two (2) copies of a structural condition report prepared, signed and sealed by an Illinois licensed Architect or Structural Engineer, attesting to the structural conditions of the building or structure. (13-196-030) | BASEMENT CEILING EXCESSIVE WATER DAMAGE DRYWALL, AND FIRE DAMAGED JOIST, 2X4 TEMP COLUMNS WITH MAKE SHIFT CINDER BLOCK FOOTING, 1ST FLOOR UNEVEN WITH SLOPE BROKEN AND CRACKED TILES, REMOVE ALL WATER DAMAGED DRYWALL, AND EXPOSE ALL DAMAGED JOIST EVIDENCE OF STRUCTURAL DAMAGED PROVIDE STRUCTURAL ENGINEER REPORT WITH PLANS AND PERMIT DANGEROUS AND HAZARDOUS 14X-1-104.1 |
CN064014 | Failed to maintain cornice in good repair and free from cracks and defects. (13-196-530(e), 13-196-641) | STONE CORNICE AND ORNAMENTAL PROJECTIONS WASHED OUT MORTAR JOINTS 14X-3-303.1.1 |
CN065024 | Failed to maintain projection from wall of building in good repair and free from cracks and defects. (13-196-530(e), 13-196-641) | EXTERIOR FRONT SIGN ABOVE DOOR ROTTED 14X-3-303.1 |
CN065034 | Failed to maintain window sill in good repair and free from cracks and defects. (13-196-530(e), 13-196-550, 13-196-641) | STONE WINDOW SILLS SHIFTED AND WASHED OUT MORTAR JOINTS 14X-3-303.1.1 |
CN070024 | Failed to repair or replace defective or missing members of porch system. (13-196-570, 13-196-641) | REAR PORCH DECKING WARPED, PROTRUDING SECTIONS AND HOLE 14X-5-505.9.1.1 |
CN103015 | Failed to maintain floor free from holes and wide cracks and free from loose, warped, protruding or rotting floor boards. (13-196-540(a) and (b)) | FLOOR UNEVEN AND LOOSE TILE CAUSING TRIP HAZARD DANGEROUS AND HAZARDOUS PROVIDE DETAIL IN PLANS AND PERMIT 14X-303.4 |
CN103035 | Repair or replace defective structural member. (13-196-530 A) | EVIDENCE OF STRUCTURAL DAMAGE IN FRONT 1ST FLOOR AND BASEMENT PROVIDE STRUCTURAL ENGINEER REPORT WATER AND FIRE DAMAGE DANGEROUS AND HAZARDOUS 14X-3-303.1.1 |
CN106015 | Failed to maintain interior stairway system in safe condition and sound repair. (13-196-570) | BASEMENT STAIRS MISSING HANDRAILS DANGEROUS AND HAZARDOUS 14X-3-304.4 |
CN135016 | Exterminate rodents in building and seal openings through which they gain access. (13-196-530 D, 13-196-630 C, 7-28-660) | INTERIOR RODENT DROPPING 14X-3-308 |
CN138106 | Remove and stop nuisance. (7-28-060) | CORRIDOR EXCESSIVE STORAGE DANGEROUS AND HAZARDOUS 14X-3-307 |
CN139016 | Remove lid or door of abandoned refrigerator, ice box, or ice chest or remove from place accessible to children. (7-28-040) | REFRIGERATOR AT REAR DANGEROUS AND HAZARDOUS 7-28-040 |
CN190019 | Arrange for inspection of premises. (13-12-100) | NO ENTRY TO 2ND FLOOR OR ADJACENT RESTAURANT 14A-1-104.7 |
CN194029 | Provide | AISLES REDUCED AND DOOR OPENING AT CASHIER 24" 32" FAILED TO MAINTAIN 36" SAME AS DOOR OPENING THROUGH-OUT DANGEROUS AND HAZARDOUS 14B-10-1018.1 |
CN197087 | Install carbon monoxide detector within 40 feet of every sleeping room in residential structure. (13-64-190, 13-64-210) A carbon monoxide detector is needed whenever there is a heating appliance on the premises that burns fossil fuel such as gas, oil, or coal, or air that is circulated through a heat exchanger. Install according to manufacturer instructions. A hard wired model requires an electrical wiring permit. In a single family residence, be sure the detector is on or below the lowest floor with a place to sleep. In a multiple dwelling residence heated by a boiler, install a detector in the same room as the boiler. Otherwise, each apartment follows single family guidelines. The owner is responsible for installation and written instructions, the tenant for testing, maintenance, and batteries. | MISSING CARBON MONOXIDE DETECTOR DANGEROUS AND HAZARDOUS 14X-5-504.9 |
EL1816 | Install additional receptacle outlets. (14E-5-560.6, 14E-5-570.10(e)) | ADD RECEPTACLES DUE TO OVER USE OF EXTENSION CORDS FOR EQUIPMENT THROUGHOUT STORE AND CASHIER STATION DANGEROUS AND HAZARDOUS |
EL1817 | Provide ground continuity for electrical cable, raceway, and enclosure. (14E-3-300.10, 14E-3-300.13) | INSTALL PROPER FITTINGS ON FLEXIBLE CONDUIT IN BASEMENT FOR REFRIGERATION EQUIPMENT DANGEROUS AND HAZARDOUS |
EL1818 | Replace broken, inoperable, or painted over receptacle or switch. (14E-4-406.4) | REPLACE RECEPTACLE AT CASHIER STATION DUE TO OVERLOADING OF RECEPTACLE DANGEROUS AND HAZARDOUS |
EL1819 | Replace defective light fixtures. (14E-4-410.20, 14E-4-410.21, 14E-4-410.22, 14E-4-410.23) | INSTALL GLOBE ONE FIXTURE IN BATH, WALK IN COOLER VERIFY LED RETROFIT KITS ARE WIRED PROPERLY AND LISTED FOR USE |
EL1820 | Support loose light fixture. (14E-4-410.30, 14E-4-410.36) | LOOSE OUTDOOR FIXTURE ON REAR EXTERIOR 2ND FLOOR IN COURTYARD |
EL1822 | Remove exposed wiring at light fixture. (14E-4-410.48) | CONCEAL OPEN WIRING AT SMOKE DETECTOR IN REAR OF STORE, AND IN AT FIXTURE IN REAR HALLWAY OF STORE DANGEROUS AND HAZARDOUS |
EL1825 | Install system III emergency lighting. (14E-7-700.6, 14E-7-700.22) | REPAIR ALL EXIT SIGNS AND VERIFY EM LIGHTING IS OPERABLE DANGEROUS AND HAZARDOUS |
EL1829 | Remove exposed wiring. (14E-3-300.4) | EXPOSED WIRING THROUGHOUT BASEMENT SPECIFICALLY AT HOT WATER HEATER AND BOTH REFRIGERATION COMPRESSORS AND IN OPEN JUNCTION BOXES FOR EXTERIOR LIGHTING FEED IN REAR COURTYARD DANGEROUS AND HAZARDOUS |
EL1830 | Remove defective armored cable. (14E-1-110.2, 14E-1-110.3, 14E-3-320.10) | REMOVE ARMORED CABLE FROM INSIDE WALK IN COOLER |
EL1839 | Replace rusted, deteriorated, or corroded conduit, cabinet, electrical box, or fitting. (14E-3-300.13, 14E-1-110.12(b)) | REPLACE CONDUIT DUE TO RUST ON EXTERIOR FRONT OF BUILDING FEEDING SIGNAGE |
EL1840 | Remove all abondoned raceways, cables, conductors, boxes and electrical equipment. 14E-1-110.1(c)) | REMOVE ABANDONED SERVICE RISER AND METER EQUIPMENT AT REAR OF BUILDING |
EL1846 | Provide insight disconnect switch for motor driven appliance over 1/8th horsepower. (14E-4-422.31(a)) | INSTALL DISCONNECTS IN BASEMENT FOR HOT WATER HEATER AND BOTH REFRIGERATION COMPRESSORS DANGEROUS AND HAZARDOUS |
EL1848 | Remove unapproved cord supply to permanently installed appliance. (14E-4-422.16) | REMOVE CORDS FEEDING CASH MACHINE AND COOLER IN STORE DANGEROUS AND HAZARDOUS |
EL1872 | Remove splice in flexible cord. (14E-4-400.13) | SPLICE IN CORD FEEDING COOLER IN FRONT OF REGISTERS FED FROM BEHIND GLASS ENCLOSURE DANGEROUS AND HAZARDOUS |
EL1875 | Receptacle outlets installed in bathrooms, garages, counter top spaces, unfinished basements and outdoor locations shall have ground fault protection for personnel.(14E-5-570.8) | INSTALL GFCI PROTECTION TO ALL RECEPTACLES IN UNFINISHED BASEMENT AREA AND REAR SINK AT CASHIER STATION DANGEROUS AND HAZARDOUS |
EL1884 | PROVIDE ELECTRICAL PERMIT IN ORDER TO REPAIR ELECTRICAL VIOLATIONS (14A-4-404.6) | |
NC2011 | Performed or allowed work to be performed without submitting plans prepared, signed and sealed by a licensed architect or registered structural engineer for approval and without obtaining a permit to perform the work. (13-32-010, 13-32-040, 13-40-020, 13-12-050) | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE TO 1ST FLOOR AND BASEMENT 1ST FLOOR PARTIONS BUILT AND BREACH IN WALLS BASEMENT TEMP 2X4 TEMP COLUMNS EXIT DOORS AND WINDOWS HAVE BEEN BLOCKED AND OR INFILLED 14A-4-401.1 |
NC2071 | Remove work performed without permit and restore building or site to original construction. (13-32-130, 13-32-290) | REMOVE ALL PARTIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN 1ST FLOOR WITH OUT A PERMIT 1ST FLOOR EVIDENCE OF ALTERATION DUE TO BREACH IN WALLS TO ADJACENT 1ST FLOOR UNIT, AND BLOCKED AND OR SEALED DOORS AND WINDOWS 14A-4-401 |
PL157047 | Stop leaking water. (18-29-102.3) | STOP WATER LEAK AT WASTE PIPING AT SINK BEHIND COUNTER DANGEROUS AND HAZARDOUS |
PL159027 | Reset loose plumbing fixture. (18-29-102.3) | THREE COMPARTMENT SINK OR LAUNDRY SINK NOT SECURED SAFELY TO WALL |
PL159057 | Repair defective plumbing and sewage system and stop odors. (18-29-102.3) | OPEN WASTE 2"PVC SUSPENDED PIPING IN BASEMENT REAR WITH SEWER ODOR DANGEROUS AND HAZARDOUS |
PL170017 | Provide floor drain with metallic strainer. (18-29-402.5) | NO FLOOR DRAIN IN MECHANICAL ROM IN REAR OF STORE |
PL171017 | Obtain permit for plumbing work before undertaking work. (18-29-106.1) | OBTAIN PLUMBING PERMIT FOR PLUMBING WORK TO BE PERFORMED |
PL171027 | Employ licensed and bonded plumber to perform plumbing work. (18-29-106.1 thru 106.2) | EMPLOY LICENSED AND BONED PLUMBING CONTRACTOR TO PERFORM PLUMBING WORK |
PL194039 | Remove | NUISANCE FOR HEALTH AND SAFETY DUE TO UNSANITARY CONDITIONS OF FIXTURES BEHIND COUNTER AND THREE COMPARTMENT SINK AND THROUGHOUT STORE 7-28-060 |
PL232011 | Obtain permit before constructing, altering, or using plumbing system. (13-12-080, 13-32-010) | PROVIDE PLANS AND PERMITS FOR SINK BEHIND BAR, THREE COMPARTMENT SINK AND LAUNDRY SINK LOCATED IN STORE UNIT |
PL232050 | Remove roughed in water supply, soil, waste, and vent piping installed without permit. (13-12-050, 13-32-010) | SINK BEHIND COUNTER WITH WASTE AND WATER SUPPLY INSTALLED WITHOUT PERMIT AND PLANS |
PL234002 | Provide proper soil/waste vent pipe material. (18-29-702) | LAUNDRY SINK WASTE NOT CONNECTED DANGEROUS AND HAZARDOUS |
PL234002 | Provide proper soil/waste vent pipe material. (18-29-702) | ACCORDIAN DRAIN PIPING AT BATHROOM LAVATORY |
PL235030 | Provide adequate support. (18-29-303.2), (18-29-308) | NO ADEQUATE SUSPENDED OVERHEAD PIPING SUPPORT ON COPPER PIPING ON FIRST FLOOR |
PL237014 | Provide ball cock, vacuum breaker, or air gap. (18-29-606.5.6) | PROVIDE VACUUM BREAKER OR AIR GAP FOR LAUNDRY TUB FAUCET HOSE CONNECTION DANGEROUS AND HAZARDOUS |
PL237020 | Provide proper material for water supply pipe. (18-29-605) | FLEXIBLE WATER SUPPLY LINES AT HOT WATER TANK IN BASEMENT DANGEROUS AND HAZARDOUS |
PL237020 | Provide proper material for water supply pipe. (18-29-605) | FLEXIBLE WATER SUPPLY LINES LOCATED AT BATHROOM LAVATORY SINK BEHIND COUNTER HAND SINK,THREE COMPARTMENT SINK LAUNDRY SINK AND TOILET |